Model

Standard capacity

Optional capacity
NIHOPHAWA-AS150 Capacity 155 L Capacity 155 – 185 L
NIHOPHAWA-AS200 Capacity 210 L Capacity 210 – 245 L
NIHOPHAWA-AS250 Capacity 253 L Capacity 253 – 295 L
NIHOPHAWA-AS300 Capacity 310 L Capacity 310 – 395 L
NIHOPHAWA-AS400 Capacity 410 L Capacity 410 – 495 L
NIHOPHAWA-AS500 Capacity 510 L Capacity 510 – 595 L
NIHOPHAWA-AS600 Capacity 610 L Capacity 610 – 695 L
NIHOPHAWA-AS800 Capacity 810 L Capacity 810 – 890 L
NIHOPHAWA-AS1000 Capacity 1010 L Capacity 1010 – 1095 L
NIHOPHAWA-AS1200 Capacity 1210 L Capacity 1210 – 1450 L
NIHOPHAWA-AS1500 Capacity 1530 L  
NIHOPHAWA-AS2000 Capacity 2010 L  
REQUEST A QUOTE
Nồi hấp cửa ngang
Nồi hấp trung tâm

NIHOPHAWA Autoclave with horizontal door (155 – 2010 L)

Autoclave owns modern vacuum technology, modern design, easy to operate and configure based on purpose of use, suitable for clinics, hospitals, medical centers.

Nồi hấp trung tâm

Configuration

  • Main unit: 01 set
  • Integrated steam generator: 01 set
  • Integrated printer: 01 set
  • Integrated compressor: 01 set
  • Booster pump: 01 set
  • Integrated vacuum pump: 01 set

Enclosed accessories:

  • Sterilization tray set with wheels,

used for fabric: 01 set

  • Transporting cart, synchronized with sterilization tray: 01 set

Manual for operation and storage: 01 book

Technical specifications

  • Operating pressure range of sterilization chamber: -0.9 kg/cm² to 2.4 kg/cm²
  • Operating temperature range of the sterilization chamber: 100 °C to 136 °C
  • Sterilization chamber: made of SUS 304 or SUS 316 stainless steel
  • Steam generator
  • Water supply: Fully automatic
  • Water level sensor: 03 pcs
  • Operating pressure: from 3.0 kg/cm² to 3.5 kg/cm²
  • Operating temperature: 143 °C to 148 °C
  • Can automatically detect water shortage and supply water even in the case of high-pressure steam generators.
  • When sterilization cycle ends, heat exchanger converts saturated steam into water before discharging it to the outside, with efficiency of approx. 97%.

Pressure range of water source for heat exchanger: from 0.1 kgf/cm² to 10 kgf/cm²

Nồi hấp tiệt trùng cửa ngang

Sterilization programs

Program 1:

Sterilization of liquid in the opening container ( Liquid Opened)

Program 2:

Sterilization of liquid in the closing container (Liquid Closed)

Program 3:

Sterilization of tools in the opening form in hospitals and clinics

Program 4:

Sterilization of tools in the closing form in hospitals and clinics

Program 5:

Simultaneous sterilization of tools, objects, solids, clothes

Program 6:

Sterilization of fabric,100% PE (Polyester) clothes and stainless steel tools.

Program 7:

Sterilization of fabric, 35/65 Cotton (Tixi) clothes and stainless steel tools.

Program 8:

Sterilization of fabric, 65/35 Cotton (CVC) clothes and stainless steel tools.

Program 9:

Sterilization of fabric,100% cotton clothes and stainless steel stools

Program 10:

Sterilization of fabric,100% cotton clothes, 131ºC heat-resistant materials and stainless steel stools

Program 11:

Sterilization of fabric,100% cotton clothes, and stainless steel stools, high-temperature resistant objects, which needs fast sterilization

Program 12:

Sterilization of fabric,100% cotton clothes, stainless steel stools and high-temperature resistant objects, which needs fast sterilization, sterilization temperature 133ºC

Program 13:

Sterilization of fabric,100% cotton clothes, stainless steel stools and high-temperature resistant objects, which needs fast sterilization, sterilization temperature 134ºC

Program 14:

Sterilization of fabric,100% cotton clothes, stainless steel stools and high-temperature resistant objects, which needs fast sterilization, sterilization temperature 135ºC

Program 15:

Sterilization of fabric,100% cotton clothes, stainless steel stools and high-temperature resistant objects, which needs fast sterilization, sterilization temperature 136ºC

Vacuum technology, mordern design

Nihophawa autoclave with a capacity of 200 – 800L is the first choice for hospitals, medical centers, and provincial hospitals that have a high flow of medical examination and treatment traffic and use a large number of medical instruments.

Printer

  • Automatically print parameters during the sterilization process, including:
  • Name of User
  • Address of User
  • Product’s model
  • Product’s Serial number
  • Starting time of operation
  • Time of performing sterilization cycles, temperature, pressure of each cycle
  • Ending time of sterilization program
  • Average temperature coefficient during sterilization (Ft).
  • Average pressure coefficient during sterilization (Ft).
  • Sterilization result: Pass or fail.
  • Signature position of operator

Safety system

  • The program automatically checks for errors and warnings, with warnings on TFT-LCD touchscreen
  • Sterilization program is not selected
  • Door of sterilization chamber is not closed or closed incorrectly
  • No compressed air or lack of air: the device stops generating steam, stop working
  • Vacuum pump is overloaded: the device stops working
  • Insufficient water for the steam generator during the sterilization cycle
  • Phase loss, phase reversal, too low power voltage
  • Defective temperature sensor, defective pressure sensor
  • The pressure of the steam generator exceeds 3.8 kgf/cm², the safety valve will automatically open
  • The pressure of the sterilization chamber exceeds 2.8 kgf/cm², the safety valve will automatically open
  • Lack of water supplying for vacuum device or without
  • The safety latch automatically closes when the sterilization chamber has a pressure of ≥ 0.2 kgf/cm² and automatically opens when the pressure of sterilization chamber is balanced with the outside pressure.
  • Warning for insufficient pressure of steam generation chamber.
  • The device automatically stops when completing the sterilization program and the pressure in the chamber is at a safe level of ± 0.1kgf/cm²
  • There is an electric emergency stop button: the sterilizer chamber’s steam relief valve opens, the power is disconnected and the device stops working.

Mechanical emergency drain valve (even in case of power failure).

GENERAL INTRODUCTION

  • Model: NIHOPHAWA-AS150-AS2000
  • Brand: NIHOPHAWA
  • Manufacturer: Hong Phat tech Co., Ltd
  • Quality management system standard: ISO9001:2015;

ISO14001:2015; ISO13485:2016; TCVN 6792:2001; CE 93/42/EEC or equivalent

Certificate of free sale for medical equipment and devices in Vietnam No.: 28/2016/BYT-TB-CT on 26th May, 2016

Nồi hấp cửa ngang Nihophawa