General introduction

The Mediburner medical waste incinerator is essential equipment in medical facilities. The device destroys medical waste effectively thanks to green technology, friendly to the environment.

  • Model: NIHOPHAWA – MEDIBURNER
  • Brand: NIHHOPHAWA
  • Quality management system complies with QCVN 02: 2012/BTNMT standard. Medical waste incinerator MEDIBURNER 08-20W applies TCCS 124:2018/HONG PHAT TECH CO., LTD dated April 20th, 2018.
  • Certificate of free sale for medical equipment and devices in Vietnam No.: 28/2016/BYT-TB-CT dated May 26th, 2016.
REQUEST A QUOTE
Lò đốt rác 08 - 50w

MEDIBURNER MEDICAL WASTE INCINERATOR

The functional unit performs output emission inspection, in accordance with the application for permission to operate the incinerator when it is accepted and handed over.

PRODUCT SPECIFICATIONS

Lò đốt rác y tế

Structure

The main incinerator with quencher: 01 set

Enclosed standard accessories:

 

  • Ash rake: 01 piece
  • Trash tray: 01 piece
  • Ash bin: 01 piece
  • Turnbuckle and cable, diameter 8mm, length 30m: 06 pieces
  • Ground wire: 01 piece
  • Chimney, 17.5m: 01 piece
  • Lightning rod and conductor (designed according to Vietnamese standards for lightning protection): 01 Set

General requirements of the medical waste incinerator

  • 100% new equipment, manufactured since 2020
  • The device has full markings, labels, origin, equipment originating in Vietnam is prioritized.
  • The manufacturer is fully certified with valid ISO 9001, ISO 14001, and ISO 13485 certifications.
  • Domestically manufactured equipment must have a Certificate of Intellectual Property and Declaration of Factory Standards of the manufacturer.
  • Provide a full user’s manual of the device
  • Provide a full description of the technology diagram, packaging, specifications and main components of the device.
  • Power supply: 1 phase, 220V/50Hz
  • The device dimensions are suitable for the location and installation area at the medical facility.
  • Trial operation, instruct the staff of medical facility to use the device.
  • The quality of the output gas meets the national technical standards QCVN 02: 2012/BTNMT on medical waste incinerators issued by the Ministry of Natural Resources and Environment.
  • The functional unit performs output emission inspection, in accordance with the application for permission to operate the incinerator when it is accepted and handed over.
  • Provide a full quote for incinerator maintenance/year after the warranty period.

Configuration

The main incinerator with quencher: 01 set

Enclosed standard accessories:

  • Ash rake: 01 piece
  • Trash tray: 01 piece
  • Ash bin: 01 piece
  • Turnbuckle and cable, diameter 8mm, length 30m: 06 pieces
  • Ground wire: 01 piece
  • Chimney, 17.5m: 01 piece
  • Lightning rod and conductor (designed according to Vietnamese standards for lightning protection): 01 Set

Medical waste incinerator Mediburn 08 – XX complies with QCVN 02: 2012/BTNMT standard. Medical waste incinerator MEDIBURNER 08-20W  applies TCCS 124:2018/HONG PHAT TECH CO., LTD dated April 20th, 2018.

The device adjusts gas for each burning chamber to fit the density of each cycle. The incinerator is controlled by an electronic system based on “Burning time” which is suitable for the density of each cycle and selected by the operator to save time and fuel.

Value of pollution parameters in the exhaust gas

No

Pollution parameters

Unit

Allowed maximum value

1

Total dust

mg/Nm3

≤ 115

2

Hydrochloric acid, HCl

mg/Nm3

≤ 50

3

Carbon monoxide, CO

tng/Nm3

≤ 200

4

Sulfur Dioxide, SO2

mg/Nm3

≤ 300

5

Nitrogen Dioxide, NOx (Calculated according to NO2)

mg/Nm3

≤ 300

6

Mercury and the compounds calculated according to mercury, Hg

mg/Nm3

≤0.5

7

Cadmium and compounds calculated according to cadmium, Cd

mg/Nm3

≤ 0.16

8

Lead and the compounds calculated according to lead, Pb

mg/Nm3

≤ 1.2

9

Total dioxin /furan, PCDD/PCDF

ngTEQ/Nm3

≤ 2.3