Model Standard capacity Optional capacity
NIHOPHAWA-AS250M Capacity 260 L Capacity from 260 – 295 L
NIHOPHAWA-AS300M Capacity 310 L Capacity from 310 – 395 L
NIHOPHAWA-AS400M Capacity 430 L Capacity from 430 – 495 L
NIHOPHAWA-AS500M Capacity 510 L Capacity from 510 – 595 L
NIHOPHAWA-AS600M Capacity 610 L Capacity from 610 – 765 L
NIHOPHAWA-AS800M Capacity 810 L Capacity from 810 – 895 L
NIHOPHAWA-AS1000M Capacity 1040 L Capacity from 1040 – 1095 L
NIHOPHAWA-AS1200M Capacity 1210 L Capacity from 1210 – 1300 L
NIHOPHAWA-AS1500M Capacity 1530 L  
NIHOPHAWA-AS2000M Capacity 2010 L  
REQUEST A QUOTE
Nồi hấp AS250M - AS2000M

NIHOPHAWA Autoclave with crank door AS250M – AS2000M

Autoclave owns modern vacuum technology, modern design, easy to operate and configure based on purpose of use, suitable for clinics, hospitals, medical centers.

Configuration

Nồi hấp AS250M - AS2000M
  • Operating pressure range of sterilization chamber: -0.9 kg/cm² to 2.4 kg/cm²
  • Operating temperature range of the sterilization chamber: 100 °C to 136 °C
  • Sterilization chamber: made of SUS 304 or SUS 316 stainless steel

Steam generator

  • Water supply: Fully automatic
  • Water level sensor: 03 pcs
  • Operating pressure: from 3.0 kg/cm² to 3.5 kg/cm²
  • Operating temperature: 143 °C to 148 °C
  • Can automatically detect water shortage and supply water even in the case of high-pressure steam generators.
  • When sterilization cycle ends, heat exchanger converts saturated steam into water before discharging it to the outside, with efficiency of approx. 97%.

Pressure range of water source for heat exchanger: from 0.1 kgf/cm² to 10 kgf/cm²

Technical information

Display screen

  • LCD-TFT screen: 7 inch; 65,535 colors
  • Resolution: 800 x 480 pixels
  • The parameters are displayed on the touchscreen.
  • Display sterilization parameters: Installed sterilization temperature, actual temperature in sterilization chamber, installed sterilization time, the remaining sterilization time, installed drying time, the remaining drying time, calendar (day, month, year), other error messages.
  • Display model: sterilization chamber, pipes, the on-off valve of device.
  • Display alphanumeric parameters such as temperature, pressure via LCD screen.
  • Display functional switches: opening and closing of soft switch valves, the status indicator of the opening and closing on the touchscreen.
  • Display diagrams
  • Display the stages of the sterilization cycle: supplying water, vacuuming, steam generating, sterilizing, rinsing, drying, ending with diagrams and language.
  • Display warnings
  • Access protection function: The user can set account, password, permissions.
  • Internet connection for monitoring and loading software
  • Port for connecting to printer.
  • Language in Vietnamese or English

Sterilization programs

  • Program 1: Sterilization of liquid in the opening container ( Liquid Opened)
  • Program 2: Sterilization of liquid in the closing container (Liquid Closed)
  • Program 3: Sterilization of tools in the opening form in hospitals and clinics
  • Program 4: Sterilization of tools in the closing form in hospitals and clinics
  • Program 5: Simultaneous sterilization of tools, objects, solids, clothes
  • Program 6: Sterilization of fabric,100% PE (Polyester) clothes and stainless steel tools.
  • Program 7: Sterilization of fabric, 35/65 Cotton (Tixi) clothes and stainless steel tools.
  • Program 8: Sterilization of fabric, 65/35 Cotton (CVC) clothes and stainless steel tools.
  • Program 9: Sterilization of fabric,100% cotton clothes and stainless steel stools
  • Program 10: Sterilization of fabric,100% cotton clothes, 131ºC heat-resistant materials and stainless steel stools
  • Program 11: Sterilization of fabric,100% cotton clothes, and stainless steel stools, high-temperature resistant objects, which needs fast sterilization
  • Program 12: Sterilization of fabric,100% cotton clothes, stainless steel stools and high-temperature resistant objects, which needs fast sterilization, sterilization temperature 133ºC
  • Program 13: Sterilization of fabric,100% cotton clothes, stainless steel stools and high-temperature resistant objects, which needs fast sterilization, sterilization temperature 134ºC
  • Program 14: Sterilization of fabric,100% cotton clothes, stainless steel stools and high-temperature resistant objects, which needs fast sterilization, sterilization temperature 135ºC
  • Program 15: Sterilization of fabric,100% cotton clothes, stainless steel stools and high-temperature resistant objects, which needs fast sterilization, sterilization temperature 136ºC

Printer:

  • Automatically print parameters during the sterilization process, including:
  • Name of User
  • Address of User
  • Product’s model
  • Product’s Serial number
  • Starting time of operation
  • Time of performing sterilization cycles, temperature, pressure of each cycle
  • Ending time of sterilization program
  • Average temperature coefficient during sterilization (Ft).
  • Average pressure coefficient during sterilization (Ft).
  • Sterilization result: Pass or fail.
  • Signature position of operator

Safety system:

  • The program automatically checks for errors and warnings, with warnings on TFT-LCD touchscreen:
  • Sterilization program is not selected
  • Door of sterilization chamber is not closed or closed incorrectly
  • No compressed air or lack of air: the device stops generating steam, stop working
  • Vacuum pump is overloaded: the device stops working
  • Insufficient water for the steam generator during the sterilization cycle
  • Phase loss, phase reversal, too low power voltage
  • Defective temperature sensor, defective pressure sensor
  • The pressure of the steam generator exceeds 3.8 kgf/cm², the safety valve will automatically open
  • The pressure of the sterilization chamber exceeds 2.8 kgf/cm², the safety valve will automatically open
  • Lack of water supplying for vacuum device or without
  • The safety latch automatically closes when the sterilization chamber has a pressure of ≥ 0.2 kgf/cm² and automatically opens when the pressure of sterilization chamber is balanced with the outside pressure.
  • Warning for insufficient pressure of steam generation chamber.
  • The device automatically stops when completing the sterilization program and the pressure in the chamber is at a safe level of ± 0.1kgf/cm²
  • There is an electric emergency stop button: the sterilizer chamber’s steam relief valve opens, the power is disconnected and the device stops working.
  • Mechanical emergency drain valve (even in case of power failure).